Slocum Maintenance Schedule

This page organizes maintenance by when it needs doing, not by which component it touches — the detailed how-to for each item lives on the relevant Glider Components page or checklist; this is the index that tells you when to go read it.

Source

Synthesized from facts already established across this site's Slocum component pages, the Post-Recovery Maintenance Checklist, and the Ballasting Procedure — see those pages for sourcing and full detail.


Before Every Deployment

Item What to confirm Detail
Vacuum ≥ 6 in Hg (shallow) / ≥ 7 in Hg (deep) — never power up without it One-Pager
O-rings Inspect every hull O-ring and sealing surface; replace as needed O-Rings
Desiccant Fresh pack installed for this deployment O-Rings
Sacrificial anodes Forward/aft continuity < 10 Ω; replace if significantly consumed Post-Recovery Checklist
Battery Correct type installed and charged; coulomb counter reset if new pack Primary · Rechargeable

After Every Recovery

Rinse after every saltwater exposure

Fresh water on the whole glider, the tail fin/rudder, the pressure transducer, and the CTD/science sensors — salt left to dry promotes corrosion and can inhibit moving parts on the next power-up.

Item Action Detail
Full rinse Whole glider, fin, pressure transducer, science sensors Post-Recovery Checklist
Thruster (if fitted) Remove hub (7/64 hex), rinse, re-grease with MoS₂, replace hub Thruster
Digifin / fin Rinse; check for fouling or a stuck/noisy fin Digifin
External inspection Hull, anodizing/paint, wet-mate connectors, air bladder, recovery lanyard Post-Recovery Checklist
Leak-detect voltages Confirm within normal range Post-Recovery Checklist

Periodic / Condition-Based

These don't happen every deployment — they're driven by cycle counts, symptoms, or a fixed interval.

Item Interval / trigger Detail
Shallow buoyancy pump 10,000-cycle service life Shallow Pump
Deep buoyancy pump Service when oil-flux troubleshooting indicates wear Deep Pump
O-ring open policy Primary batteries: every open (i.e. every mission). Rechargeable: commonly once a year O-Rings
Compass Degauss a suspect (magnetized) battery pack if calibration won't converge Compass
Software updates Read the release's readme.txt before updating One-Pager

Storage

  • Recharge or otherwise service batteries as planned before shelving.
  • Confirm desiccant is installed and the glider is sealed with a proper vacuum.
  • Store at +10 to +25 °C for optimum battery life.
  • If crating, use all straps and secure cylindrical parts so they can't roll.

See the Post-Recovery Maintenance Checklist for the full storage-prep checklist.